YJV 0.6/1KV 交联聚乙烯绝缘聚氯乙烯护套电力电缆

2020-01-26
YJV   0.6/1KV 交联聚乙烯绝缘聚氯乙烯护套电力电缆
导体标称截面绝缘厚度护套厚度电缆近似外径电缆近似重量导体直流电阻试验电压电缆载流量
在空气中直埋土壤中
mm 2mmmmmmkg/kmW/kmKVAA
1×1.50.71.55.853 12.13.52535
1×2.50.71.56.268 7.413.53045
1×40.71.56.787 4.613.54560
1×60.71.57.2110 3.083.55570
1×100.71.58115 1.833.57595
1×160.71.58.9220 1.153.5100125
1×250.91.510.4345 0.7273.5140160
1×350.91.511.5424 0.5243.5175190
1×5011.51355 0.3873.5210225
1×701.11.514770 0.2683.5270280
1×951.11.516.41040 0.1933.5340335
1×1201.21.517.81290 0.1533.5400380
1×1501.4220.61590 0.1243.5460425
1×1851.6222.51944 0.09913.5530480
1×2401.7224.92410 0.07543.5625555
1×3001.82.527.33076 0.06013.5720630
1×40022.534.13642 0.04703.5815705
导体标称截面绝缘厚度护套厚度电缆近似外径电缆近似重量导体直流电阻试验电压电缆载流量
在空气中直埋土壤中
mm 2mmmmmmkg/kmW/kmKVAA
2×1.50.71.89.4103 12.13.52530
2×2.50.71.810.2131 7.413.53035
2×40.71.811.2168 4.613.54050
2×60.71.812.2216 3.083.55060
2×100.71.815.2328 1.833.56580
2×160.71.817.3461 1.153.585100
2×250.91.820.4659 0.7273.5115130
2×350.91.822.4868 0.5243.5145155
2×5011.820.21116 0.3873.5175185
2×701.11.822.51514 0.2683.5220225
2×951.11.825.42017 0.1933.5270270
2×1201.21.928.32526 0.1533.5315305
2×1501.4231.33139 0.1243.5360345
导体标称截面绝缘厚度护套厚度电缆近似外径电缆近似重量导体直流电阻试验电压电缆载流量
在空气中直埋土壤中
mm 2mmmmmmkg/kmW/kmKVAA
3×1.50.71.59.8145 12.13.52530
3×3.50.71.510.7185 7.413.53035
3×40.71.511.8250 4.613.54050
3×60.71.512.9320 3.083.55060
3×100.71.514.6450 1.833.56580
3×160.71.516.5640 1.153.585100
3×250.9220.8940 0.7273.5115130
3×350.9223.21260 0.5243.5145155
3×501226.41670 0.3873.5175185
3×701.1229.92280 0.2683.5220225
3×951.1233.33020 0.1933.5270270
3×1201.22.537.83795 0.1533.5315305
3×1501.42.541.74750 0.1243.5360345
3×1851.62.544.65654 0.09913.5420390
3×2401.72.550.17243 0.07543.5500455
3×3001.8355.68832 0.06013.5580520
导体标称截面绝缘厚度护套厚度电缆近似外径电缆近似重量导体直流电阻试验电压电缆载流量
在空气中直埋土壤中
mm 2mmmmmmkg/kmW/kmKVAA
4×1.50.71.510.6139 12.13.52126
4×2.50.71.511.5150 7.413.52835
4×40.71.512.8253 4.613.53746
4×60.71.514337 3.083.54756
4×100.71.515.9501 1.833.56476
4×160.7219.1778 1.153.58498
4×250.9222.71160 0.7273.5115126
4×350.9225.41554 0.5243.5141152
4×5012292148 0.3873.5172181
4×701.1232.92928 0.2683.5218222
4×951.12.537.73954 0.1933.5369267
4×1201.22.541.64925 0.1533.5313305
4×1501.4347.66238 0.1243.5359344
4×1851.6350.67562 0.09913.5405383
4×2401.7356.49660 0.07543.5451422
4×4001.83.562.211758 0.06013.5497461
导体标称截面绝缘厚度护套厚度电缆近似外径电缆近似重量导体直流电阻试验电压电缆载流量
在空气中直埋土壤中
mm 2mmmmmmkg/kmW/kmKVAA
5×1.50.71.812.4192 12.13.52125
5×2.50.71.813.5252 7.413.52833
5×40.71.814.8359 4.613.53744
5×60.71.816.2472 3.083.54654
5×100.71.819.6713 1.833.56373
5×160.71.822.41053 1.153.58494
5×250.91.827.21583 0.7273.5109120
5×350.91.930.52134 0.5243.5132144
导体标称截面绝缘厚度护套厚度电缆近似外径电缆近似重量导体直流电阻试验电压电缆载流量
在空气中直埋土壤中
mm 2mmmmmmkg/kmW/kmKVAA
3×4+1×2.50.71.512.5236 4.613.54055
3×6+1×40.71.513.7316 3.083.55065
3×10+1×60.71.515.4460 1.833.57090
3×16+1×100.71.517.5679 1.153.590110
3×25+1×160.9221.81065 0.7273.5130150
3×35+1×160.9223.81368 0.5243.5165185
3×50+1×251227.41901 0.3873.5200210
3×70+1×351.12312585 0.2683.5258265
3×95+1×501.12.534.83718 0.1933.5320315
3×120+1×701.22.539.74443 0.1533.5380360
3×150+1×701.42.542.95326 0.1243.5440400
3×185+1×951.6347.46628 0.09913.5505435
3×240+1×1201.7352.78501 0.07543.5603524
3×300+1×1501.83.55810320 0.06013.5700605
导体标称截面绝缘厚度护套厚度电缆近似外径电缆近似重量导体直流电阻试验电压电缆载流量
mm 2mmmmkg/kmW/kmKV在空气中直埋土壤中
mmmmAA
3×50+2×2510.91.828.22268 0.3873.5159169
3×70+2×351.10.9232.83116 0.2683.5195205
3×95+2×501.112.1374176 0.1933.5237245
3×120+2×701.21.12.341.45375 0.1533.5273278
3×150+2×701.41.12.444.56305 0.1243.5310309
3×185+2×951.61.12.549.27889 0.09913.5355347
3×240+2×1201.71.22.754.710051 0.07543.5416398
导体标称截面绝缘厚度护套厚度电缆近似外径电缆近似重量导体直流电阻试验电压电缆载流量
mm 2mmmmkg/kmW/kmKV在空气中直埋土壤中
mmmmAA
4×50+1×2510.91.828.22268 0.3873.5159169
4×70+1×351.10.9232.83116 0.2683.5195205
4×95+1×501.112.1374176 0.1933.5237245
4×120+1×701.21.12.341.45375 0.1533.5273278
4×150+1×701.41.12.444.56305 0.1243.5310309
4×185+1×951.61.12.549.27889 0.09913.5355347
4×240+1×1201.71.22.754.710051 0.07543.5416398
YJV22   0.6/1KV 交联聚乙烯绝缘聚氯乙烯护套铠装电力电缆
导体标称截面绝缘厚度护套厚度电缆近似外径电缆近似重量导体直流电阻试验电压电缆载流量
在空气中直埋土壤中
mm 2mmmmmmkg/kmW/kmKVAA
2×40.71.814.4325 4.613.53746
2×60.71.815.4387 3.083.54756
2×100.71.818.4538 1.833.56476
2×160.71.820.5700 1.153.58498
2×250.91.823.6939 0.7273.5115126
2×350.91.825.61174 0.5243.5141152
2×5011.823.41393 0.3873.5172181
2×701.11.826.22132 0.2683.5218222
2×951.11.929.52694 0.1933.5269267
2×1201.22333276 0.1533.5313305
2×1501.42.136.13997 0.1243.5359344
导体标称截面绝缘厚度护套厚度电缆近似外径电缆近似重量导体直流电阻试验电压电缆载流量
在空气中直埋土壤中
mm 2mmmmmmkg/kmW/kmKVAA
3×1.50.71.513273 12.13.52126
3×3.50.71.513.9321 7.41,3.52835
3×40.71.515390 4.613.53746
3×60.71.516.1471 3.083.54756
3×100.71.517.8622 1.833.56476
3×160.7221.51005 1.153.58498
3×250.9224.81371 0.7273.5115126
3×350.9227.21724 0.5243.5141152
3×501230.42247 0.3873.5172181
3×701.12.535.33023 0.2683.5218222
3×951.12.538.73825 0.1933.5269267
3×1201.22.542.24642 0.1533.5313305
3×1501.4347.55767 0.1243.5359344
3×1851.6352.86892 0.09913.5405383
3×2401.7358.18017 0.07543.5451422
3×3001.83.563.49142 0.06013.5497461
导体标称截面绝缘厚度护套厚度电缆近似外径电缆近似重量导体直流电阻试验电压电缆载流量
mm 2mmmmkg/kmW/kmKV在空气中直埋土壤中
mmmmAA
3×50+2×2510.9232.72876 0.3873.5161167
3×70+2×351.10.92.238.34150 0.2683.5197203
3×95+2×501.112.342.65345 0.1933.5239242
3×120+2×701.21.12.547.26696 0.1533.5275274
3×150+2×701.41.12.650.57746 0.1243.5314305
3×185+2×951.61.12.755.39499 0.09913.5354341
3×240+2×1201.71.22.961.211878 0.07543.5414392
导体标称截面绝缘厚度护套厚度电缆近似外径电缆近似重量导体直流电阻试验电压电缆载流量
mm 2mmmmkg/kmW/kmKV在空气中直埋土壤中
mmmmAA
4×50+1×2510.9233.93153 0.3873.5161167
4×70+1×351.10.92.239.94554 0.2683.5197203
4×95+1×501.112.444.75896 0.1933.5239242
4×120+1×701.21.12.548.77248 0.1533.5275274
4×150+1×701.41.12.652.78620 0.1243.5314305
4×185+1×951.61.12.857.910520 0.09913.5354341
4×240+1×1201.71.2364.213199 0.07543.5414392
导体标称截面绝缘厚度护套厚度电缆近似外径电缆近似重量导体直流电阻试验电压电缆载流量
在空气中直埋土壤中
mm 2mmmmmmkg/kmW/kmKVAA
5×2.50.71.817252 7.413.52833
5×40.71.818.3359 4.613.53743
5×60.71.819.7472 3.083.54754
5×100.71.823.5713 1.833.56471
5×160.71.8261053 1.153.58492
5×250.91.9311583 0.7273.5110118
5×350.92.134.32134 0.5243.5134141


分享